logo

EXL210LED

Zone :

Description

Ex II 3G Ex ec op is IIC T5 Gc

Ex II 2D Ex tb op is IIIC T60°C Db

 

Explosion-proof lighting fixture with LED modules. Designed for use in zones 21 and 2,22 with explosion hazard of gases, vapors and mists of flammable liquids with air, as well as flammable dust and fibers. The fixture has ATEX KDB 15ATEX0049X, OBAC 20 ATEX 0205X and IECEx KDB 20.0003X certificates, as well as CNBOP approval no. 5300/2024 and PZH certificate.

Downloads
EXL210LED EXL210LED EXL210LED EXL210LED

Types Comparison

 Please see datasheet for complete table with additional information.

 Code

 Wattage

Efficiency (lm/W)

Ambient Temp. (°C)

EXL210LED-0600-E2 16,2 170 -40 to +45
EXL210LED-0600-E4 31,5 174 -40 to +45
EXL210LED-1200-E4 38 170 -40 to +45
EXL210LED-1200-E8 62,2 176 -40 to +45
EXL210LED-1500-E6 46,9 175 -40 to +45

Electrical Features

  • Connection terminals:  2,5mm2
  • Input voltage: 230V, 0/50-60 Hz
  • Light source: Intrinsically safe LED modules
  • Power factor: >0,97
  • Cable inlets: Ø20
  • Overvoltage protection: 2kV

Mechanical Features

  • Housing: Glass Fibre Reinforced Polyester (GRP)
  • Diffuser: UV Stabilised Polycarbonate
  • Ingress protection: IP66, IP67
  • Protection class: I
  • Mounting: on the surface with bracket

Work Parameters

  • Ambient Temperatures: -40°C to +60°C
  • Lifetime: >70.000h L80 B10

Photometrical Parameters

  • CRI: >80
  • Colour temperature: 4000K

Certificate Information

  • Standard and ZB
    • Ex II 2G Ex eb mb op is IIC T5 Gb
    • Ex II 2D Ex tb op is IIIC T55°C Db or T70°C Db
  • A3, ZBC, ZBD
    • Ex II 3G Ex ec IIC T5 Gc
    • Ex II 2D Ex tb IIIC T60°C Db
  • ZBT, ZBS, ZBR, ZBH, ZBM
    • Ex II 3G Ex ec IIC T5 Gc
    • Ex II 3D Ex tC IIIC T60°C Dc
Find Out How Hazlite Can Deliver Customised Solutions For You!
Hazardous Lighting Solutions
Tanhouse Lane, Widnes, WA8 0ZA, United Kingdom

© 2025 Hazlite. All Rights Reserved.

Scroll to Top